NEX205 AHU Controller
0
NEX205 AHU Controller
"2xUniversal input
Size - 96Wx96Hx60D in mm
Display - Upper - 1 “ , Lower - 0.56”
Upto 6 digital inputs
Upto 7 relays
IP66 (IEC) / NEMA 4X protection
Sampling time 50ms/200ms programmable
Isolated 2 x 0/4~20 mA or 0-10 V DC for control / retransmission output
Isolated RS485 / Modbus RTU communication
Housing material - ABS plastic, grade, UL94V-0"
Quick view
Radix Make Carbon Dioxide Transmitter - CDE201
0
Radix Make Carbon Dioxide Transmitter - CDE201
Model Name/Number- CDE201
Measuring Range- 0~10000
Brand- Radix
Color- White
Material- Polycarbonate (White)
Display Type- Dual row LCD display
Weight- 0.14 Kg
Calibration- Automatic Self Calibration (ASC) algorithm
Power- <2W
Features- NDIR CO2 sensor with dual channel detection technology for superior stability in occupied and non
Port- Isolated RS485
Supported baud rate- 4800, 9600, 19200, 57600, 115200
Mutual isolation between supply & RS485 output- 1000V AC RMS, 50 Hz / 1 second, 500V / minute
Terminals- Screw type suitable for cable 14~22 AWG
Torque- 4kgf.cm / M2.5
Resistance output- Resistance output for various thermistors & RTD sensors Pt100/Pt1000
Ambient, storage- -20 ~ +70 DegreeC
Ambient, operation- 0 ~ +50 DegreeC
Relative humidity- 0 ~ 100% RH
Mounting- Wall mount
› 8 universal analog inputs
› 8 thermocouples, Pt50, Pt100, Cu53, 0~100 mV, 0~5 V, 0~10 V, 1~5 V, 0/4~20 mA
› Isolated RS485/MODBUS RTU, Upto 57600 Baud or MODBUS/TCP & Telnet multidrop
communication for PLC, SCADA, etc.
› 85~265 VAC or 18~35 V DC supply
› 4 key, 6 level programming
› Maximum 4 or 8 relay outputs
› Powerful, flexible SCADA software available
Quick view
Humidity, Temperature & Dewpoint Transmitter - HTW201
0
Humidity, Temperature & Dewpoint Transmitter - HTW201
2 x 2-wire, 4-20 mA or 0-10 VDC outputs
? Any or both outputs can be assigned to Relative Humidity or Temperatureor Dewpoint or specific derived physical quantity
? RH & T range selection, parameter configuration and calibration with- USB to serial converter (DCC501)- Handheld configurator (HHC202)- Inbuilt LCD and 3 keys
? Heartbeat LED for device health status
? Isolated Modbus® RTU or BACnet MS/TP (RS485)
? Derived physical quantities- Dewpoint- Absolute Humidity- Heat Index- Enthalpy
? High degree of protection against condensation & pollution
? Surface (Wall), Duct, Outside & Remote sensor option available
? Convenient installation with 2-part housing with fixed back and removable electronics
? Integral sensor (default) or remote sensor
? Flush mount application
Quick view
Mineral Insulated RTD Sensor with Terminal Head
0
Mineral Insulated RTD Sensor with Terminal Head
An RTD (Resistance Temperature Detector) is a sensor whose resistance changes as its temperature changes. The resistance increases as the temperature of the sensor increases. The resistance vs temperature relationship is well known and is repeatable over time. An RTD is a passive device. It does not produce an output on its own. External electronic devices are used to measure the resistance of the sensor by passing a small electrical current through the sensor to generate a voltage. Typically 1 mA or less measuring current, 5 mA maximum without the risk of self-heating.
Lengths upto 50 meters
Flexible sheath -50 to 400°C range
Termination : Aluminium head with threaded cap and chain
Different types of terminal heads are available
1/2"BSP (F) single cable entry with single compression gland
Dual entries and glands are optional
SS316 sheath material
Elements are terminated into nickel plated brass terminals mounted on high purity ceramic terminal block mounted on spring loaded stainless steel disc
Spring loading protects ceramic terminal block from damage due to impact and vibrations. It ensures proper contact at the hot end inside the thermowell in thermocouple-thermowell assemblies