Humidity, Temperature & Dewpoint Transmitter - HTW201
2 x 2-wire, 4-20 mA or 0-10 VDC outputs
? Any or both outputs can be assigned to Relative Humidity or Temperatureor Dewpoint or specific derived physical quantity
? RH & T range selection, parameter configuration and calibration with- USB to serial converter (DCC501)- Handheld configurator (HHC202)- Inbuilt LCD and 3 keys
? Heartbeat LED for device health status
? Isolated Modbus® RTU or BACnet MS/TP (RS485)
? Derived physical quantities- Dewpoint- Absolute Humidity- Heat Index- Enthalpy
? High degree of protection against condensation & pollution
? Surface (Wall), Duct, Outside & Remote sensor option available
? Convenient installation with 2-part housing with fixed back and removable electronics
? Integral sensor (default) or remote sensor
? Flush mount application
Evapoler's Hybrid AC system has been engineered to save on energy by 60-70 % as compared to mechanical air conditioning.
The Hybrid AC performance increases with increase in ambient temperature, so it is capable of giving fail-safe cooling performance in hot summer & Monsoon season.
Hybrid Units are advanced climate control systems that combine multiple cooling technologies to deliver efficient and sustainable temperature management. These units integrate three stages of cooling- direct, indirect cooling and cooling coils. This innovative approach provides superior performance compared to standard evaporative systems and is more cost-effective than conventional air handling units (AHUs). Designed as all-season, customizable solutions, hybrid units are ideal for a wide range of climates and contribute to sustainability by reducing energy consumption and environmental impact.
The Hydro Multi-E booster set presents a highly reliable and versatile pressure booster solution that provides you with plug-and-pump installation, fast and easy set-up and optimal energy efficiency. Unique to the Hydro Multi-E is its lack of a conventional control unit. In this intelligent solution, the control of the system lies within the pumps, which are able to communicate with each other. Since each pump can function as the controlling unit, there is full redundancy if a sensor or pump should fail. Use together with Grundfos GO for remote monitoring of your installation in apartment buildings, hotels, hospitals, schools, irrigation, wash and clean systems and fire hydrants.
Indoor Air Quality Diffuser for two Way Solution by combining UVC Air Sterilization & Enhanced Forced Ventilation. Aluminium Extrusion constructed diffuser enclosing UVC lights with front plaque face & G.I constructed plenum enclosing EC fan for forced ventilation. Powder coated finish.
The IAQ will monitor up to 6 parameters that include Particulate Matter (PM1, PM2.5, PM4 & PM10), Volatile Organic Compounds, Carbon Dioxide, Formaldehyde, Humidity & Temperature and provide either a BACnet® MSTP or MODBUS signal for connection to a building automation system. The IAQ features field-replaceable sensor modules, a full-color capacitive touch screen LCD that’s user-configurable, and a configurable alarm relay output. All this is housed in a new modern, quick-mount enclosure.
At IES, we believe Digital Twins are the key to decarbonising the built environment. Fully scalable from a single building to an entire city, our ICL technology goes beyond BIM to create a live Digital Twin which responds and behaves like its real world counterpart. Delivering the data-driven information needed to uncover significant energy, carbon, capital and operational savings. While taking account of resource use, transport, social and economic factors.
InDirect Evaporative Coolers
Indirect Cooling
A single stage Indirect Evaporative Coolers use the advantages of cooling using water evaporation without increasing humidity in the supply air. This is done through our special DRI COOL module.
A 2-stage evaporative cooling system is an advanced cooling system that utilizes indirect evaporative cooling modules followed by a direct cooling section. The overall result is lower dry bulb temperature as compared to a direct only evaporative coolers.
A third stage can be added as a cooling coil which is turned on when the second direct evaporative cooling section is off. This is based on the ambient conditions.
These units are also offered in very large air volumes and with all sensors, controls and electrical packaged on board the unit.